{"product_id":"steuer-leistungselektronik-control-electronics-fur-pelletbrenner-attack-ek025-ersatzteil-h30806b","title":"H30951B Control and power electronics for ATTACK DPX Combi Pellet 25\/30\/35, PELH30A \u0026 PELHB25","description":"\u003ch2 class=\"mt-6 mb-2 font-semibold text-3xl\" data-streamdown=\"heading-1\"\u003eH30951B Control\/power electronics for Attack pellet burner\u003c\/h2\u003e  \u003cp\u003eThe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B Control\/Power Electronics\u003c\/span\u003e is the central control and power module for various \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAttack Pellet Burner\u003c\/span\u003e and \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCombined boiler systems\u003c\/span\u003eIt takes over the complete control, monitoring and power management of all relevant components in pellet operation.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eCompatible attack devices (excerpt)\u003c\/h3\u003e  \u003cp\u003eAccording to exploded views and spare parts lists, the H30951B is installed in, among others, the following Attack devices:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK DPX COMBI PELLET 25, 30, 35\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ez.B. Device family \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003e#110 PELH30ACP\u003c\/span\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eConstruction periods u.a.: 10\/2014 – 7\/2018 and from 8\/2018 (depending on the version)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELH30A\u003c\/span\u003e (Pellet burner unit, from 10\/2014)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELHB25\u003c\/span\u003e (Pellet burner 25 kW, from 10\/2014)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eThe H30951B is listed there as a separate item in the spare parts plan and is part of the assemblies with the codes z.B.:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELH30A\u003c\/span\u003e, \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePELHB25\u003c\/span\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIn combination with other relevant components such as H30970A, H30806B, H30808, H30809, H30820, H30980, ADF25640, PELH30830A u.v.m.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eThis makes the H30951B particularly suitable for \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eAttack pellet burners in the power range of 25 to 35 kW\u003c\/span\u003e relevant, which are found in various boiler series such as \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eDPX Combi Pellet\u003c\/span\u003e be used.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eFunction and tasks of the H30951B\u003c\/h3\u003e  \u003cp\u003eThe H30951B is a combined \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eControl and power electronics\u003c\/span\u003eIt handles both the intelligent control (microcontroller control) and the control of the consumers (power section):\u003c\/p\u003e  \u003col class=\"list-inside list-decimal whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"ordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBurner control (Control Electronics)\u003c\/span\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eEvaluation of sensors (z.BTemperature sensor, exhaust gas temperature, flame sensor, possibly vacuum sensor)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eControl of the process flow of: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eStarting and ignition process\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eTransition to continuous operation\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePower modulation\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003econtrolled shutdown process\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eImplementation of the heating programs and safety strategies stored in the device\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePower control (Power Electronics)\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eControl of: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePellet auger(s)\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eIgnition device\/ignition cartridge\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBlower\/combustion fan\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ecleaning and discharge mechanisms (if applicable)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eSwitching of consumers via relays or...electronic circuit breakers\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePower supply for the control electronics and the connected sensors\/actuators\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eSecurity and incident management\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMonitoring of overtemperature, flame loss, underpressure or exhaust gas faults\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIntroduction of \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003esafe shutdown\u003c\/span\u003e in case of malfunction\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eEdition of \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eError codes\/fault messages\u003c\/span\u003e to the control unit of the Attack boiler\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cp\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCommunication with control unit and boiler control\u003c\/span\u003e\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eInterface to the operating and display unit (display, buttons)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eTransfer of status, temperature and fault information\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eInteraction with the higher-level boiler or heating control system (release, power request)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003c\/ol\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eTypical errors that indicate a control system malfunction\u003c\/h3\u003e  \u003cp\u003eThe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B Control\/Power Electronics\u003c\/span\u003e is considered \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ecomplete replacement module\u003c\/span\u003e used when:\u003c\/p\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ethe \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePellet burner no longer starts\u003c\/span\u003e or goes out uncontrollably\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIndividual outputs (ignition, auger, fan) can no longer be controlled, even though the components themselves are fine.\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eRecurring or unexplained error messages\u003c\/span\u003e problems occur that cannot be attributed to sensors, wiring, or peripherals\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eVisible damage to the electronics is present (burnt components, defective relays, swollen capacitors)\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp\u003eBy replacing the H30951B, the \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003efull range of functions of the pellet burner\u003c\/span\u003e It can be restored, provided all other components are intact.\u003c\/p\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eAdvantages of the original H30951B for Attack pellet burners\u003c\/h3\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eOriginal spare part\u003c\/span\u003e matching the corresponding Attack series\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003etailored to: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK DPX COMBI PELLET 25, 30, 35\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELH30A\u003c\/span\u003e\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eATTACK PELHB25\u003c\/span\u003e\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eensures \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ecorrect combustion\u003c\/span\u003e, high efficiency and stable performance in pellet operation\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003esecures the \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCompliance with safety functions\u003c\/span\u003e according to manufacturer's specifications\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eoptimal compatibility with other Attack components (z.B. PELH30851, PELH30800A, PELH30807B, PELH30830A, sensors TS215, TH31, TH23A etc.)\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eImportant information regarding ordering and exchanges\u003c\/h3\u003e  \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003ePlease note before ordering: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e  \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eBoiler\/burner nameplate\u003c\/span\u003e check (z.BATTACK DPX COMBI PELLET 25\/30\/35, Year of manufacture\/Serial number)\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eexisting electronic circuit board to the marking \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B\u003c\/span\u003e control\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eFor safety reasons, replacement should be carried out by a \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eSpecialist company\/heating specialist\u003c\/span\u003e take place: \u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMains voltage 230 V\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eCorrect connection assignment and parameterization required\u003c\/li\u003e  \u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eIf necessary, adaptation to existing sensors and peripherals\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eScope of delivery\u003c\/h3\u003e  \u003cul\u003e  \u003cli\u003e1x original Attack control board \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eH30951B\u003c\/span\u003e  \u003c\/li\u003e  \u003c\/ul\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":56543461146972,"sku":"APSP","price":310.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/h30951b-steuer-leistungselektronik-fur-attack-dpx-combi-pellet-253035-pelh30a-pelhb25-7132351.webp?v=1770692015","url":"https:\/\/fr.gemashop.de\/en\/products\/steuer-leistungselektronik-control-electronics-for-pellet-burner-attack-ek025-replacement-part-h30806b","provider":"GEMA Shop","version":"1.0","type":"link"}