{"product_id":"mpm-wood-plus-6-holzvergaserkessel-6kw","title":"MPM Wood Plus 6 kW wood gasification boiler - log boiler A+","description":"\u003cp data-start=\"706\" data-end=\"935\"\u003eThe MPM Wood Plus 6 is a modern wood gasification boiler with a nominal output of 6 kW for logs.\u003cbr data-start=\"799\" data-end=\"802\"\u003eIt meets Ecodesign requirements and achieves energy efficiency class A+. Ideal for single-family homes with buffer storage operation.\u003c\/p\u003e  \u003chr data-start=\"937\" data-end=\"940\"\u003e  \u003ch2 data-start=\"942\" data-end=\"966\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"968\" data-end=\"1302\"\u003e⭐ Efficient wood gasification with 82.9% efficiency at nominal output\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e⭐ Energy efficiency class A+ (EEI 117) – complies with EU Ecodesign 2015\/1189\u003cbr data-start=\"1108\" data-end=\"1111\"\u003e⭐ Robust welded steel construction with ceramic burner\u003cbr data-start=\"1170\" data-end=\"1173\"\u003e\u0026amp; Suitable for open and closed operation (up to 1.5 bar)\u003cbr data-start=\"1235\" data-end=\"1238\"\u003e⭐ Optimized for buffer tank operation (minimum 300 liters recommended)\u003c\/p\u003e  \u003chr data-start=\"1304\" data-end=\"1307\"\u003e  \u003ch1 data-start=\"1309\" data-end=\"1348\"\u003eMPM Wood Plus 6 kW wood gasification boiler\u003c\/h1\u003e  \u003ch2 data-start=\"1350\" data-end=\"1380\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1382\" data-end=\"1547\"\u003eThe MPM Wood Plus 6 is a water-bearing wood gasification boiler with manual feeding for logs (moisture content ≤ 25%).\u003cbr data-start=\"1515\" data-end=\"1518\"\u003eIt is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"1549\" data-end=\"1652\"\u003e  \u003cli data-start=\"1549\" data-end=\"1570\"\u003e  \u003cp data-start=\"1551\" data-end=\"1570\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1571\" data-end=\"1593\"\u003e  \u003cp data-start=\"1573\" data-end=\"1593\"\u003esmall residential buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1594\" data-end=\"1652\"\u003e  \u003cp data-start=\"1596\" data-end=\"1652\"\u003eWorkshops or commercial premises with low heating requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1654\" data-end=\"1745\"\u003eThe system operates exclusively at nominal power in conjunction with a buffer storage tank.\u003c\/p\u003e  \u003chr data-start=\"1747\" data-end=\"1750\"\u003e  \u003ch2 data-start=\"1752\" data-end=\"1773\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1775\" data-end=\"1970\"\u003eThe carburetor technology ensures a two-stage combustion:\u003cbr data-start=\"1834\" data-end=\"1837\"\u003eFirst, the wood is degassed, then the resulting wood gases are completely burned in a ceramic combustion chamber.\u003c\/p\u003e  \u003cp data-start=\"1972\" data-end=\"1985\"\u003eThe result:\u003c\/p\u003e  \u003cul data-start=\"1987\" data-end=\"2097\"\u003e  \u003cli data-start=\"1987\" data-end=\"2010\"\u003e  \u003cp data-start=\"1989\" data-end=\"2010\"\u003estable combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2011\" data-end=\"2033\"\u003e  \u003cp data-start=\"2013\" data-end=\"2033\"\u003elow emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2034\" data-end=\"2052\"\u003e  \u003cp data-start=\"2036\" data-end=\"2052\"\u003ehigh efficiency\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2053\" data-end=\"2097\"\u003e  \u003cp data-start=\"2055\" data-end=\"2097\"\u003eBurning time up to approx. 4 hours per filling\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2099\" data-end=\"2204\"\u003eWith a fuel consumption of approximately 1.5 kg\/h, the boiler operates economically and in a resource-saving manner.\u003c\/p\u003e  \u003chr data-start=\"2206\" data-end=\"2209\"\u003e  \u003ch2 data-start=\"2211\" data-end=\"2235\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2237\" data-end=\"2352\"\u003eThe MPM Wood Plus 6 is made of certified steel boiler plate in a welded construction.\u003cbr data-start=\"2324\" data-end=\"2327\"\u003eThe construction includes:\u003c\/p\u003e  \u003cul data-start=\"2354\" data-end=\"2629\"\u003e  \u003cli data-start=\"2354\" data-end=\"2401\"\u003e  \u003cp data-start=\"2356\" data-end=\"2401\"\u003elarge loading chamber (~30 dm³\/approx. 10 kg wood)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2402\" data-end=\"2426\"\u003e  \u003cp data-start=\"2404\" data-end=\"2426\"\u003emovable cast iron grate\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2427\" data-end=\"2453\"\u003e  \u003cp data-start=\"2429\" data-end=\"2453\"\u003eMetal-ceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2454\" data-end=\"2507\"\u003e  \u003cp data-start=\"2456\" data-end=\"2507\"\u003evertical flue gas ducts with turbulence element\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2508\" data-end=\"2534\"\u003e  \u003cp data-start=\"2510\" data-end=\"2534\"\u003emechanical tension regulator\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2535\" data-end=\"2574\"\u003e  \u003cp data-start=\"2537\" data-end=\"2574\"\u003eThermometer in the upper boiler area\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2575\" data-end=\"2629\"\u003e  \u003cp data-start=\"2577\" data-end=\"2629\"\u003eDBV-1 connection for thermal overheating protection\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2631\" data-end=\"2680\"\u003eThermal insulation is provided by 40 mm of mineral wool.\u003c\/p\u003e  \u003chr data-start=\"2682\" data-end=\"2685\"\u003e  \u003ch2 data-start=\"2687\" data-end=\"2708\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2710\" data-end=\"2791\"\u003eThe boiler meets the requirements of Regulation (EU) 2015\/1189 (Ecodesign).\u003c\/p\u003e  \u003cp data-start=\"2793\" data-end=\"2811\"\u003eKey values:\u003c\/p\u003e  \u003cul data-start=\"2813\" data-end=\"3002\"\u003e  \u003cli data-start=\"2813\" data-end=\"2862\"\u003e  \u003cp data-start=\"2815\" data-end=\"2862\"\u003eSeasonal space heating energy efficiency: 80%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2863\" data-end=\"2893\"\u003e  \u003cp data-start=\"2865\" data-end=\"2893\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2894\" data-end=\"2930\"\u003e  \u003cp data-start=\"2896\" data-end=\"2930\"\u003eEnergy Efficiency Index (EEI): 117\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2931\" data-end=\"2947\"\u003e  \u003cp data-start=\"2933\" data-end=\"2947\"\u003ePM: 15 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2948\" data-end=\"2965\"\u003e  \u003cp data-start=\"2950\" data-end=\"2965\"\u003eOGC: 18 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2966\" data-end=\"2983\"\u003e  \u003cp data-start=\"2968\" data-end=\"2983\"\u003eCO: 653 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2984\" data-end=\"3002\"\u003e  \u003cp data-start=\"2986\" data-end=\"3002\"\u003eNOx: 163 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3004\" data-end=\"3058\"\u003eIt corresponds to class 5 according to PN-EN 303-5:2021-09.\u003c\/p\u003e  \u003chr data-start=\"3060\" data-end=\"3063\"\u003e  \u003ch2 data-start=\"3065\" data-end=\"3102\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3104\" data-end=\"3146\"\u003eThe MPM Wood Plus 6 can be operated:\u003c\/p\u003e  \u003cul data-start=\"3148\" data-end=\"3265\"\u003e  \u003cli data-start=\"3148\" data-end=\"3173\"\u003e  \u003cp data-start=\"3150\" data-end=\"3173\"\u003ein the open heating system\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3174\" data-end=\"3265\"\u003e  \u003cp data-start=\"3176\" data-end=\"3265\"\u003ein a closed heating system (with diaphragm expansion vessel and safety devices)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3267\" data-end=\"3298\"\u003eKey operational requirements:\u003c\/p\u003e  \u003cul data-start=\"3300\" data-end=\"3463\"\u003e  \u003cli data-start=\"3300\" data-end=\"3359\"\u003e  \u003cp data-start=\"3302\" data-end=\"3359\"\u003eRecommended buffer storage volume: at least 330 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3360\" data-end=\"3398\"\u003e  \u003cp data-start=\"3362\" data-end=\"3398\"\u003eMinimum return temperature: 65 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3399\" data-end=\"3431\"\u003e  \u003cp data-start=\"3401\" data-end=\"3431\"\u003eOperating temperature: 60–90 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3432\" data-end=\"3463\"\u003e  \u003cp data-start=\"3434\" data-end=\"3463\"\u003eMaximum operating pressure: 1.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3465\" data-end=\"3538\"\u003eA thermostatic anti-condensate valve (65 °C) is strongly recommended.\u003c\/p\u003e  \u003chr data-start=\"3540\" data-end=\"3543\"\u003e  \u003ch1 data-start=\"3545\" data-end=\"3563\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3565\" data-end=\"4622\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3565\" data-end=\"3583\"\u003e  \u003ctr data-start=\"3565\" data-end=\"3583\"\u003e  \u003cth data-start=\"3565\" data-end=\"3575\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3575\" data-end=\"3583\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3603\" data-end=\"4622\"\u003e  \u003ctr data-start=\"3603\" data-end=\"3645\"\u003e  \u003ctd data-start=\"3603\" data-end=\"3616\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3616\" data-end=\"3645\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3646\" data-end=\"3670\"\u003e  \u003ctd data-start=\"3646\" data-end=\"3655\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3655\" data-end=\"3670\"\u003eWood Plus 6\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3671\" data-end=\"3706\"\u003e  \u003ctd data-start=\"3671\" data-end=\"3684\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3684\" data-end=\"3706\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3707\" data-end=\"3734\"\u003e  \u003ctd data-start=\"3707\" data-end=\"3726\" data-col-size=\"sm\"\u003eNominal heating output\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3726\" data-end=\"3734\"\u003e6 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3735\" data-end=\"3771\"\u003e  \u003ctd data-start=\"3735\" data-end=\"3761\" data-col-size=\"sm\"\u003eGenerated useful heat (Pn)\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"3761\" data-end=\"3771\"\u003e6.2 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3772\" data-end=\"3803\"\u003e  \u003ctd data-start=\"3772\" data-end=\"3797\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-start=\"3797\" data-end=\"3803\" data-col-size=\"sm\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3804\" data-end=\"3841\"\u003e  \u003ctd data-start=\"3804\" data-end=\"3834\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-start=\"3834\" data-end=\"3841\" data-col-size=\"sm\"\u003e117\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3842\" data-end=\"3879\"\u003e  \u003ctd data-start=\"3842\" data-end=\"3871\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-start=\"3871\" data-end=\"3879\" data-col-size=\"sm\"\u003e80%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3880\" data-end=\"3922\"\u003e  \u003ctd data-start=\"3880\" data-end=\"3912\" data-col-size=\"sm\"\u003eEfficiency at rated power\u003c\/td\u003e  \u003ctd data-start=\"3912\" data-end=\"3922\" data-col-size=\"sm\"\u003e82.9%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3923\" data-end=\"3958\"\u003e  \u003ctd data-start=\"3923\" data-end=\"3950\" data-col-size=\"sm\"\u003eThermal efficiency\u003c\/td\u003e  \u003ctd data-start=\"3950\" data-end=\"3958\" data-col-size=\"sm\"\u003e89%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3959\" data-end=\"4001\"\u003e  \u003ctd data-start=\"3959\" data-end=\"3974\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-start=\"3974\" data-end=\"4001\" data-col-size=\"sm\"\u003e5 (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4002\" data-end=\"4025\"\u003e  \u003ctd data-start=\"4002\" data-end=\"4015\" data-col-size=\"sm\"\u003eheating surface\u003c\/td\u003e  \u003ctd data-start=\"4015\" data-end=\"4025\" data-col-size=\"sm\"\u003e1.0 m²\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4026\" data-end=\"4062\"\u003e  \u003ctd data-start=\"4026\" data-end=\"4050\" data-col-size=\"sm\"\u003eWater quantity in the boiler\u003c\/td\u003e  \u003ctd data-start=\"4050\" data-end=\"4062\" data-col-size=\"sm\"\u003e40 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4063\" data-end=\"4080\"\u003e  \u003ctd data-start=\"4063\" data-end=\"4070\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e  \u003ctd data-start=\"4070\" data-end=\"4080\" data-col-size=\"sm\"\u003e840 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4081\" data-end=\"4106\"\u003e  \u003ctd data-start=\"4081\" data-end=\"4096\" data-col-size=\"sm\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-start=\"4096\" data-end=\"4106\" data-col-size=\"sm\"\u003e455 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4107\" data-end=\"4132\"\u003e  \u003ctd data-start=\"4107\" data-end=\"4121\" data-col-size=\"sm\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-start=\"4121\" data-end=\"4132\" data-col-size=\"sm\"\u003e1020 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4133\" data-end=\"4157\"\u003e  \u003ctd data-start=\"4133\" data-end=\"4143\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-start=\"4143\" data-end=\"4157\" data-col-size=\"sm\"\u003eapprox. 170 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4158\" data-end=\"4193\"\u003e  \u003ctd data-start=\"4158\" data-end=\"4179\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-start=\"4179\" data-end=\"4193\" data-col-size=\"sm\"\u003eapprox. 30 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4194\" data-end=\"4236\"\u003e  \u003ctd data-start=\"4194\" data-end=\"4223\" data-col-size=\"sm\"\u003eRecommended buffer storage\u003c\/td\u003e  \u003ctd data-start=\"4223\" data-end=\"4236\" data-col-size=\"sm\"\u003e300 liters\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4237\" data-end=\"4270\"\u003e  \u003ctd data-start=\"4237\" data-end=\"4258\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-start=\"4258\" data-end=\"4270\" data-col-size=\"sm\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4271\" data-end=\"4306\"\u003e  \u003ctd data-start=\"4271\" data-end=\"4297\" data-col-size=\"sm\"\u003eMaximum operating temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4297\" data-end=\"4306\"\u003e90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4307\" data-end=\"4346\"\u003e  \u003ctd data-start=\"4307\" data-end=\"4337\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4337\" data-end=\"4346\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4347\" data-end=\"4379\"\u003e  \u003ctd data-start=\"4347\" data-end=\"4368\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4368\" data-end=\"4379\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4380\" data-end=\"4414\"\u003e  \u003ctd data-start=\"4380\" data-end=\"4405\" data-col-size=\"sm\"\u003eFlow\/return connection\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4405\" data-end=\"4414\"\u003e40 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4415\" data-end=\"4447\"\u003e  \u003ctd data-start=\"4415\" data-end=\"4433\" data-col-size=\"sm\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4433\" data-end=\"4447\"\u003e100–120 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4448\" data-end=\"4494\"\u003e  \u003ctd data-start=\"4448\" data-end=\"4472\" data-col-size=\"sm\"\u003eExhaust system required\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4472\" data-end=\"4494\"\u003eapprox. 0.19–0.20 mbar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4495\" data-end=\"4546\"\u003e  \u003ctd data-start=\"4495\" data-end=\"4519\" data-col-size=\"sm\"\u003eMinimum chimney dimensions\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4519\" data-end=\"4546\"\u003e160x160 mm or Ø140 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4547\" data-end=\"4579\"\u003e  \u003ctd data-start=\"4547\" data-end=\"4572\" data-col-size=\"sm\"\u003eMinimum chimney height\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4572\" data-end=\"4579\"\u003e7 m\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4580\" data-end=\"4622\"\u003e  \u003ctd data-start=\"4580\" data-end=\"4593\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"4593\" data-end=\"4622\"\u003eFirewood ≤ 25% moisture\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"4624\" data-end=\"4627\"\u003e  \u003ch2 data-start=\"4629\" data-end=\"4644\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"4646\" data-end=\"4731\"\u003e  \u003cli data-start=\"4646\" data-end=\"4684\"\u003e  \u003cp data-start=\"4648\" data-end=\"4684\"\u003eMPM Wood Plus 6 wood gasification boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4685\" data-end=\"4708\"\u003e  \u003cp data-start=\"4687\" data-end=\"4708\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4709\" data-end=\"4731\"\u003e  \u003cp data-start=\"4711\" data-end=\"4731\"\u003eWarranty documents\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4733\" data-end=\"4736\"\u003e  \u003ch2 data-start=\"4738\" data-end=\"4761\"\u003eAccesories \u0026amp; Recommendation\u003c\/h2\u003e  \u003cp data-start=\"4763\" data-end=\"4818\"\u003eFor optimal and safe operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"4820\" data-end=\"5026\"\u003e  \u003cli data-start=\"4820\" data-end=\"4851\"\u003e  \u003cp data-start=\"4822\" data-end=\"4851\"\u003eBuffer storage tank from 300 liters\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4852\" data-end=\"4898\"\u003e  \u003cp data-start=\"4854\" data-end=\"4898\"\u003eThermostatic anti-condensate valve 55 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4899\" data-end=\"4925\"\u003e  \u003cp data-start=\"4901\" data-end=\"4925\"\u003eDBV-1 Thermostatic Valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4926\" data-end=\"4953\"\u003e  \u003cp data-start=\"4928\" data-end=\"4953\"\u003eReturn flow boosting group\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4954\" data-end=\"4986\"\u003e  \u003cp data-start=\"4956\" data-end=\"4986\"\u003eDraft regulator for chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4987\" data-end=\"5026\"\u003e  \u003cp data-start=\"4989\" data-end=\"5026\"\u003eAcid-resistant chimney liner\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5028\" data-end=\"5088\"\u003eSuitable components can be found at:\u003cbr data-start=\"5066\" data-end=\"5069\"\u003e\u003ca data-start=\"5069\" data-end=\"5088\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/gemashop.de\"\u003ehttps:\/\/gemashop.de\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-eri7ssmm.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e  \u003chr data-start=\"5090\" data-end=\"5093\"\u003e  \u003ch2 data-start=\"5095\" data-end=\"5128\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cul data-start=\"5130\" data-end=\"5446\"\u003e  \u003cli data-start=\"5130\" data-end=\"5194\"\u003e  \u003cp data-start=\"5132\" data-end=\"5194\"\u003eInstallation exclusively by a qualified specialist company\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5195\" data-end=\"5229\"\u003e  \u003cp data-start=\"5197\" data-end=\"5229\"\u003eOperation only with buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5230\" data-end=\"5270\"\u003e  \u003cp data-start=\"5232\" data-end=\"5270\"\u003eReturn temperature continuously ≥ 65 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5271\" data-end=\"5335\"\u003e  \u003cp data-start=\"5273\" data-end=\"5335\"\u003eSafety distance to flammable materials: at least 1 m\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5336\" data-end=\"5381\"\u003e  \u003cp data-start=\"5338\" data-end=\"5381\"\u003eChimney draft of approximately 0.20 mbar required\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5382\" data-end=\"5446\"\u003e  \u003cp data-start=\"5384\" data-end=\"5446\"\u003eNo operation with plastics or unsuitable fuels\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5448\" data-end=\"5489\"\u003eFailure to comply will result in loss of warranty.\u003c\/p\u003e  \u003chr data-start=\"5491\" data-end=\"5494\"\u003e  \u003ch1 data-start=\"5496\" data-end=\"5501\"\u003eFAQ\u003c\/h1\u003e  \u003cp data-start=\"5503\" data-end=\"5669\"\u003e\u003cstrong data-start=\"5503\" data-end=\"5546\"\u003e1.Is the MPM Wood Plus 6 eligible for funding?\u003c\/strong\u003e\u003cbr data-start=\"5546\" data-end=\"5549\"\u003eIt meets Ecodesign requirements and energy efficiency class A+. National funding conditions must be checked individually.\u003c\/p\u003e  \u003cp data-start=\"5671\" data-end=\"5798\"\u003e\u003cstrong data-start=\"5671\" data-end=\"5709\"\u003e2. Is a buffer storage tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"5709\" data-end=\"5712\"\u003eYes. Operation is only possible with a buffer tank of at least 300 liters.\u003c\/p\u003e  \u003cp data-start=\"5800\" data-end=\"5950\"\u003e\u003cstrong data-start=\"5800\" data-end=\"5864\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"5864\" data-end=\"5867\"\u003eYes, with a diaphragm expansion vessel, safety valve and thermal relief valve.\u003c\/p\u003e  \u003cp data-start=\"5952\" data-end=\"6089\"\u003e\u003cstrong data-start=\"5952\" data-end=\"5994\"\u003e4. Which type of wood may be used?\u003c\/strong\u003e\u003cbr data-start=\"5994\" data-end=\"5997\"\u003eFirewood with a maximum moisture content of 25%, ideally air-dried for at least two years.\u003c\/p\u003e  \u003cp data-start=\"6091\" data-end=\"6186\"\u003e\u003cstrong data-start=\"6091\" data-end=\"6128\"\u003e5. What is the efficiency?\u003c\/strong\u003e\u003cbr data-start=\"6128\" data-end=\"6131\"\u003e82.9% at rated power; thermal efficiency 89%.\u003c\/p\u003e  \u003cp data-start=\"6188\" data-end=\"6301\"\u003e\u003cstrong data-start=\"6188\" data-end=\"6238\"\u003e6. What return temperature is required?\u003c\/strong\u003e\u003cbr data-start=\"6238\" data-end=\"6241\"\u003eAt least 55 °C to avoid low-temperature corrosion.\u003c\/p\u003e  \u003cp data-start=\"6303\" data-end=\"6417\"\u003e\u003cstrong data-start=\"6303\" data-end=\"6340\"\u003e7. How long does a filling burn?\u003c\/strong\u003e\u003cbr data-start=\"6340\" data-end=\"6343\"\u003eUp to approximately 4 hours, depending on fuel quality and system design.\u003c\/p\u003e  \u003chr data-start=\"6419\" data-end=\"6422\"\u003e  \u003ch2 data-start=\"6424\" data-end=\"6432\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"6434\" data-end=\"6659\"\u003eThe MPM Wood Plus 6 is a compact, Ecodesign-compliant wood gasification boiler for smaller buildings with buffer storage operation.\u003cbr data-start=\"6559\" data-end=\"6562\"\u003eAn efficient, robust and technically sophisticated solution for sustainable heating with firewood.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":54128283353436,"sku":"MPMWP6","price":1955.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-14-kw-holzvergaserkessel-a-klasse-5-o178-2565436.webp?v=1770691938","url":"https:\/\/fr.gemashop.de\/en\/products\/mpm-wood-plus-6-wood-carburettor-boiler-6kw","provider":"GEMA Shop","version":"1.0","type":"link"}